Secured Trading Service

Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer

Yueqing Lifang Electric Co., Ltd.
  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • 24-hour daily cyclic automatic timing, multiple ON/OFF periods customizable
  • 200-hour power failure memory, no time recalibration needed after power recovery
  • 3 working modes: Auto program, permanent ON, permanent OFF
  • Wide voltage compatibility, suitable for lighting, water pumps, fans, advertising light boxes and other equipment

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer

Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer pictures & photos
Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer pictures & photos
Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer pictures & photos
Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer pictures & photos
Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer pictures & photos
Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer pictures & photos
Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
  • Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
  • Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
    Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
  • Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
    Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
  • Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
    Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
  • Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
    Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
  • Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
    Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
  • Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer
    Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure Timer

Find Similar Products

Product Description

Ah711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure TimerAh711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure TimerAh711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure TimerAh711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure TimerAh711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure TimerAh711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure TimerAh711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure TimerAh711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure TimerAh711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure TimerAh711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure TimerAh711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure TimerAh711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure TimerAh711-R 200h Mechanical Time Switch, 24-Hour Cycle Mechanical Timer, 200-Hour Mechanical Timing Retention After Power Failure TimerAH711-R 200h Mechanical Time Switch English User Manual


Dimension & Wiring Diagra
Circuit Wiring Sketch

1. Product Overview

This AH711-R 200h is a 24-hour cycle analog mechanical timer with clockwork power reserve, driven by synchronous motor. It supports daily cyclic automatic on/off control for lighting, pumps, ventilation, heating and other electrical equipment.
  • Model: AH711-R 200h
  • Cycle: 24-hour daily repeatable program
  • Power reserve: 200 hours mechanical timing after power failure
  • Protection grade: IP30 (indoor use only, dust-proof, no water splash allowed)

2. Technical Specifications

Item Parameter
Supply Voltage AC 110V~240V, 50/60Hz
Contact Rating 16A 230VAC resistive load
Minimum Setting Interval 10 minutes per tab
Total Programmable Segments 144 adjustable tabs around dial
Motor Power Consumption ≤1.5 VA
Mechanical Life ≥100,000 switching cycles
Power Reserve Duration 200 hours (clockwork maintains timing without mains power)
Operating Temperature -10°C ~ +50°C
Storage Temperature -20°C ~ +60°C
Housing Material Flame-retardant ABS plastic + transparent PC cover
Mounting Size 72mm × 72mm, standard 86-type panel / DIN rail mount

3. Terminal Definition & Wiring Instruction

Terminals 1, 2: Mains power input (connect live & neutral for internal synchronous motor M) Terminals 3, 4, 5: Load control single-pole contact
  • Terminal 4 = Common pole
  • Terminal 3 = Normally closed (NC)
  • Terminal 5 = Normally open (NO)

Wiring Steps

  1. Cut off main power supply before wiring to avoid electric shock.
  2. Connect AC mains wire to terminal 1 & 2.
  3. Connect your load circuit between terminal 4 and target contact (NO=5 for auto-switch ON at set time; NC=3 for auto-switch OFF at set time).
  4. Tighten all screw terminals firmly to prevent overheating.

4. Operation & Programming Guide

Step 1: Set Current Real Time

Rotate the central clock dial clockwise until the clock hands align with the actual local time.

Step 2: Set Timing Periods

The outer blue ring has detachable plastic tabs:
  • Pull the tab OUT: Timer turns ON the load during this time period
  • Push the tab IN: Timer keeps the load OFF during this time period Each single tab equals 10 minutes of timing window. You can combine multiple tabs to set long continuous working hours.

Step 3: Manual Override Switch

The small black slide knob at bottom right:
  • Auto mode: Knob at middle position, follow programmed tabs automatically
  • Manual ON: Slide up, keep load powered permanently
  • Manual OFF: Slide down, cut load power forcibly

5. Key Features

  1. 200-hour power failure memory: Built-in clockwork spring mechanism keeps the dial running for 200 hours after power cut, no need to reset time after power recovery.
  2. Wide universal voltage: Compatible with global 110V~240V 50/60Hz mains.
  3. Single-channel heavy-duty contact: Max 16A load capacity for most household & light industrial appliances.
  4. Easy daily cyclic programming, no complicated digital setup required.
  5. Flame retardant housing, transparent dust-proof cover to view dial status directly.

6. Application Scenarios

  • Garden lighting, street light automatic control
  • Water pumps, fish tank circulation equipment
  • Fan, ventilation, heating & cooling equipment
  • Advertising light boxes, factory auxiliary equipment
  • Agricultural greenhouse timing devices

7. Safety Warnings

  1. Only for indoor installation (IP30), do not install in humid, rain or corrosive gas environment.
  2. The load current must not exceed rated 16A, otherwise contact burnout may occur.
  3. All wiring work must be completed by qualified electricians with power disconnected.
  4. Do not disassemble the internal clockwork motor module, damage will void warranty.
  5. Avoid installing near high-temperature heat sources to prevent plastic housing deformation.

8. Dimension Drawing

Overall size: 72mm (width) × 72mm (height) × 47.5mm (depth), max body length 69mm. Standard square panel cutout for cabinet embedded mounting.

 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR253106". Items marked "verified" are certified.

Watch Video
Watch Video
Yueqing Lifang Electric Co., Ltd.
Yueqing Lifang Electric Co., Ltd.
Yueqing Lifang Electric Co., Ltd.
Yueqing Lifang Electric Co., Ltd.
Yueqing Lifang Electric Co., Ltd.
Yueqing Lifang Electric Co., Ltd.
Yueqing Lifang Electric Co., Ltd.
Yueqing Lifang Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
108 Sutai Road, Sulan Village, Liushi Town, Yueqing City, Wenzhou, Zhejiang, China
verified Plant Area
350 square meters
verified Registered Capital
2,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Ningbo Port
verified Minimum Order Quantity
1 Pc
verified Supply Chain Partners
20

Our Production Capability & Technical Expertise

verified Main Products
Isolating Switch, Relay, Power Transformer, AC Contactors, Pushbutton Switches, Proximity Switches, Photoelectric Switches, High Voltage Cabinets, Water Proof Box, Temperature Controller
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instruction but no written records
verified Customization Options
Customization from Samples, Full Customization, Minor Customization, Customization from Designs, Flexible customization
verified ODM Service Available
Yes
verified Traceability of Raw Materials
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2010-08-18
verified Export Year
15 Years
verified Main Markets
Southeast Asia/ Mideast
verified Repeat Buyers Choice
50%~80%
verified Number of Foreign Trading Staff
1
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
No

FAQ

How long does the timer keep time after power failure?
It features a 200-hour mechanical power reserve, maintaining the dial and timing without mains power.
What is the maximum load current this switch can handle?
The contact rating is 16A at 230VAC for resistive loads.
Can this timer be used outdoors?
No, it is IP30 rated for indoor use only and is not splash-proof or suitable for humid/rainy environments.
How is the timing programmed?
It uses 144 detachable tabs on the outer ring, where each tab represents a 10-minute interval.
What is the minimum setting interval?
The minimum timing unit is 10 minutes per adjustable tab.
Does the product support customization?
Yes, the supplier offers full customization, minor customization, and customization from samples or designs.
What is the minimum order quantity?
The minimum order quantity is 1 piece.
What are the lead times for delivery?
Both peak and off-peak season lead times are within 15 working days.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now