• DTY-H220d75g Fully Isolated Single-Phase AC Voltage Regulator Module
  • DTY-H220d75g Fully Isolated Single-Phase AC Voltage Regulator Module
  • DTY-H220d75g Fully Isolated Single-Phase AC Voltage Regulator Module
  • DTY-H220d75g Fully Isolated Single-Phase AC Voltage Regulator Module
  • DTY-H220d75g Fully Isolated Single-Phase AC Voltage Regulator Module
  • DTY-H220d75g Fully Isolated Single-Phase AC Voltage Regulator Module

DTY-H220d75g Fully Isolated Single-Phase AC Voltage Regulator Module

Type: Moudel
Usage: Voltage Regulator Moudel
Theory: Electronic
Carry Mode: Asynchronous Counter
Carry Base: Binary Counter
Mechanism: Electronic
Samples:
US$ 25.90/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
DTY-H220D75G
PLC Type
SE PLC
Voltage
380/220V
Transport Package
Box, Ctns
Specification
4-20mA
Trademark
LF/E
Origin
China
HS Code
8536411000
Production Capacity
500, 000PCS /Year

Product Description

Fully isolated single-phase AC voltage regulator module DTY-H220D75E DTY-H220D75F DTY-H220D75G DTY-H220D75H

The last digit of the model is the input control signal type, E means 0-5V; F means 0-10V; G means 4-20mA; H means 1-5V.
 
Fully isolated single-phase AC voltage regulation module (hereinafter referred to as single-phase voltage regulation module DTY) is a synchronous transformer, phase detection circuit, phase shift trigger circuit and output thyristor in one, when the size of the control voltage is changed, the output can be changed The triggering phase angle of the SCR can realize the voltage regulation of single-phase alternating current. According to the different output thyristor devices, it is divided into three types: a common type of bidirectional thyristor, an enhanced type with two unidirectional thyristors in anti-parallel, and a half-wave type with one unidirectional thyristor. According to the rated voltage of single-phase AC load, it is divided into two categories: 220V and 380V, and four categories according to the different control signals: E, F, G, H, etc. The following is a table of specifications and models: (Note: The current rating is SCR inside the module Maximum current effective value)
2 Model list
 

Types of Electric current Choose one of 220V load
last E\F\G\H
Choose one of the last E\F\G\H of 380V load
 
Enhanced 15A DTY-H220D15E DTY-H380D15E
35A DTY-H220D35E DTY-H380D35E
55A DTY-H220D55E DTY-H380D55E
75A DTY-H220D75E DTY-H380D75E
120A DTY-H220D120E DTY-H380D120E
150A DTY-H220D150E DTY-H380D150E
190A DTY-H220D190E DTY-H380D190E
240A DTY-H220D240E DTY-H380D240E
290A DTY-H220D290E DTY-H380D290E
350A DTY-H220D350E DTY-H380D350E
normal type 10A DTY-220D10E DTY-380D10E
25A DTY-220D25E DTY-380D25E
40A DTY-220D40E DTY-380D40E
Half-wave 10A DTY-220D10XE DTY-380D10XE
25A DTY-220D25XE DTY-380D25XE
50A DTY-220D50XE DTY-380D50XE
Note: The last digit of the model is the input control signal type, E means 0-5V; F means 0-10V; G means 4-20mA; H means 1-5V.
 
 
  E series F series G series H series
Input range  0~5V 0~10V 4~20mA 1~5V
input resistance >30KΩ >30KΩ 250Ω >30KΩ
Effective input range 0.75~4.75V 1.5~9.5V 5~19mA 1.25~4.75V
Phase shift angle range 150°~0° 150°~0° 150°~0° 150°~0°
 
1.2.
is the output terminal, that is, the corresponding random solid-state relay output terminal, the voltage level is 380VAC specification, and can be used on the power grid less than 420Vac. According to the difference of thyristor inside the module, it is also divided into ordinary type, enhanced type and half-wave type like solid state relay. The half-wave type is a unidirectional thyristor used as the output contact, and only regulates the positive half cycle of the AC voltage (the anode of the unidirectional thyristor inside the module is connected to the 1. end, and the cathode is connected to the 2.end).
3.4.It is the primary part of the internal synchronous transformer of the module, which is divided into two specifications of 220VAC and 380VAC: the module of 220VAC specification is allowed to be used on the power grid in the range of 165-240VAC, and the module of 380VAC specification is allowed to be used on the power grid of 285-420VAC, 3.4. regardless of the end of the same name .
COM is the internal ground terminal, CON is the control terminal, and the +5V terminal is internally generated. It is only used for manual control of the power supply. The strong current part of 1.2.3.4. is fully isolated from the weak current part of +5V, CON and COM.
Half-wave Used for electric shock airport closure
normal type Small current module or dv/dt with lower requirements
Enhanced High current module or dv/dt demanding occasions
220V 220V loop load
380V 380V loop load (that is, add two live wires to the load)
Current capacity selection 1. For resistive loads, the current level of SSR should be greater than or equal to twice the rated current of the load.
2.When the load is an AC motor, the current level of SSR must be greater than or equal to 6-7 times the rated current of the motor.
3. For AC electromagnet, intermediate relay wire protection, inductance coil and other loads, the current level of SSR should be greater than or equal to 4 times the rated load current.
4.When compensating for capacitor-type loads, the current level of SSR must be greater than 5 times the rated current of the load.
5. The transformer requires 5 times or more of the transformer primary rated current, and the special inductive and capacitive loads should also amplify the SSR current margin according to actual experience.


The single-phase AC voltage regulation module can be equipped with the following radiators:
 
E-40/F-70/F-100/G-120/G-150/G-185/A-250/A-330
 
1. If the voltage applied to the load through 1.2. is inconsistent with the voltage of 3.4., please declare the voltage of the two, our company can customize it for the user, but the phase of the two must be the same, and 3.4. must be 220VAC or 380VAC, 50HZ Voltage level. There is no polarity between 1.2.room and 3.4.room. For example: if the rated voltage of a load is 36VAC (the voltage is reduced by a 220V power grid via a transformer), if a single-phase voltage regulation module of 75A is selected, a module of type TY-H36D75P-220 can be customized from our company, where 1.2. feet are connected in series with the load Connected to 36V grid, 3.4. pin connected to 220V grid.
2. CON to COM must be positive. If the polarity is reversed, the output terminal will be out of control (fully open or fully closed). When the control terminal CON changes from 0-5V, the voltage on the AC load is adjustable from 0 volts to the maximum value (for resistive loads). Where CON is about 0-0.75V, it is a fully closed area, and the output of the module is reliably turned off; CON is about 0.75V-4.75V, which is an adjustable area, that is, as the control voltage increases, the conduction angle α is from 150 The temperature decreases linearly from ° to 0°, and the voltage on the AC load increases from tens of volts to the maximum value. When CON is around 4.75V-5V, it is a fully open area, and the voltage on the AC load is the maximum value.
3. The input impedance of the E, F, and H series CON to COM is greater than 30KΩ, and the input impedance of the G series CON to COM is 250Ω. The +5V voltage signal is only provided to the manual potentiometer, not used for other purposes. The resistance of the potentiometer selected is between 2-10KΩ.
4. The speed regulation of single-phase AC asynchronous motors should usually use frequency converters. Only the soft characteristic loads such as fans and pump motors, or torque motors can be regulated by voltage regulation.
5. Three single-phase voltage regulation modules cannot be used to regulate the three-phase load on a three-phase power grid (see Three-phase Voltage Regulation ).
6. The insulation voltage between the weak current part, the strong current part and the module bottom plate is greater than 2000VAC.
7. The heating value of the entire module is calculated by the actual current amperage of the load multiplied by 1.5 watts/ampere. The radiator can be selected from E-40, F-70, F-100 and G series.
8. Please refer to the single-phase AC solid-state relays for the precautions regarding the selection and protection of current levels .
9. If the load has high requirements on the linearity of voltage regulation and voltage regulation, please increase the voltage negative feedback module .
 

DTY-H220d75g Fully Isolated Single-Phase AC Voltage Regulator ModuleDTY-H220d75g Fully Isolated Single-Phase AC Voltage Regulator ModuleDTY-H220d75g Fully Isolated Single-Phase AC Voltage Regulator ModuleDTY-H220d75g Fully Isolated Single-Phase AC Voltage Regulator Module
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now